ArticlesArticles Most Helpful ArticlesMost Helpful Articles Language SettingsLanguage Settings LoginLogin
RSS Feeds
DrillDown Icon Table of Contents Back
 . . . . . . . . . . . . .
DrillDown Icon Hardware and Software Requirements for Installing SQL Server
DrillDown Icon List of Modules Converted to MANEX Client Server
DrillDown Icon Installing SQL Server
DrillDown Icon System Administrator
DrillDown Icon Security System
DrillDown Icon Accounting Setup
DrillDown Icon System Setup
DrillDown Icon Operations Manuals
DrillDown Icon Sales
DrillDown Icon Inventory Management
DrillDown Icon Material Planning
DrillDown Icon Production
DrillDown Icon Quality/Engineering
DrillDown Icon Statisical Quality Control (SQC) (OPTIONAL Module)
DrillDown Icon Prerequisites
DrillDown Icon Introduction
DrillDown Icon Fields & Definitions
DrillDown Icon How To ....
DrillDown Icon Enter the Defect Data Information
DrillDown Icon Enter the Defect Data Information for the DPMO by Employee Report
DrillDown Icon SQC - Setup an SQC Template
DrillDown Icon SQC - Data Viewing & Analysis
DrillDown Icon FAQ's - SQC
DrillDown Icon Corrective Action Request (CAR) (OPTIONAL Module)
DrillDown Icon Integrated BOM & AVL
DrillDown Icon BOM Import
DrillDown Icon ECO, BCN & Deviation Control Mgmt (EBD) (OPTIONAL Module)
DrillDown Icon Work Order Traveler Setup
DrillDown Icon Product Data Management (PDM) (OPTIONAL Module)
DrillDown Icon PDM Standard Process Specification
DrillDown Icon Administration
DrillDown Icon Accounting
DrillDown Icon System Utilities
DrillDown Icon SQL Server Memory Settings and Performance
DrillDown Icon Definitions
DrillDown Icon How to schedule and automate backups of SQL Server databases in SQL Server Express
DrillDown Icon SQL_FAQ's
  Email This ArticlePrint PreviewPrint Current Article and All Sub-Articles
 
SQC - Setup an SQC Template

Enter the SQLMANEX.EXE (within the ManEx root directory)
This action will then prompt the user for a password

The following screen will be displayed, select Quality/Engineering/Statistical Quality Control (SQC) Module  

 

The following screen will be displayed:

Template Selection Setup

This is the first screen to be used in the module. In this screen, STATISTICAL QUALITY CONTROL graphics are created by selecting parameters to be considered in the graph.

This screen operates differently than all other ManEx screens. When bringing up the SQC module, the user is first presented with a template screen from which to choose parameters to be included in the information displayed. 

When the user enters the system, he/she may select how they want to start the process of selection.  Click on the Customer, Part Number or Work Order radial.

Clicking on the Customer radial will bring up the following selection screen:

 Select either Customer List or All Customers.
 

Selecting by Customer List will bring up the following selection screen:

 

Type the Customer into the red box or highlight and double click.

 
 
If the user selects by All Customers, the following screen will appear, listing All Customers, Work Centers, and Defects: 

 

If the start is from Part Number, the following selection will appear:  

If the user selects Product Number List, the following list will appear:

Type the Part Number into the red box or highlight and double click.

 
 
If the user selects All Products, the following screen will appear, listing All Part Numbers, Work Centers, and Defects: 

 

 If the user starts with the Work Order start, the following selection will appear:

 

If the user selects the Work Order List option, the following screen will appear:

User may Select from:  Open, Closed/Cancelled or All

The Select from:   Work Order Number, Product Number, Customer, Sales Order Number, or All 

Enter complete or partial info into the Red box or highlight and double click.

 
If the user selects All Work Orders the following screen will appear listing all Work Orders, all Work Centers, and all Defects. 

 

In the Work Order section, choose from All, One or Some.  If you’ve selected one, highlight the desired work order.  If you want more than one, depress the Ctrl key and click on the ones desired.

 
 

In the Work Center section, choose from All, One or Some.  If you’ve selected one, highlight the desired work center.  If you want more than one, depress the Ctrl key and click on the ones desired. 

 

Make the same selection in the Defect List section.  If you want all defects displaying as per the System Setup, check the Defect List box.

 

To make a new selection, depress the New Selection button.

Template Detail Screen

Pressing on the Template Detail tab brings up the following screen:

Enter the Date Range, From and To.  Mark the Radial for the view by Daily, Weekly, Monthly, or Yearly.

Mark the radial for the User Defined Limits for DPMO chart:  Lower Limit, Central Line, Upper Limit or Reset.  Indicate Central Line amount in box.

Mark the radial for the User Defined Limits for pChart:   Lower Limit, Central Line, Upper Limit or Reset.  Indicate Central Line amount in box.

Indicate the user defined goal for the Yield Chart.
 
To Save this template for future use go back to the Template Selection/Setup tab enter in a name and depress the Save button.  The Template will be saved in the Viewing Template field for future use.  
 
 

 