ArticlesArticles Most Helpful ArticlesMost Helpful Articles Language SettingsLanguage Settings LoginLogin
RSS Feeds
DrillDown Icon Table of Contents Back
 . . . . . . . . . . . . .
DrillDown Icon Utility
DrillDown Icon Sales Management
DrillDown Icon Inventory Management
DrillDown Icon Packing List Management
DrillDown Icon RMA Receiver
DrillDown Icon PO Receiving & DMR
DrillDown Icon Kitting, Allocating & Shortage Mgmt
DrillDown Icon Inventory Control Mgmt (ICM)
DrillDown Icon Inventory Control Mgmt (ICM)
DrillDown Icon Inventory Handling
DrillDown Icon IPS Upload
DrillDown Icon Lookup Manufacturer Part Number from XL List
DrillDown Icon Inventory Cycle Count
DrillDown Icon Prerequisites
DrillDown Icon Introduction
DrillDown Icon Fields & Definitions
DrillDown Icon How To .....
DrillDown Icon Reports
DrillDown Icon FAQ
DrillDown Icon How can I clear out a Cycle Count that was started in error?
DrillDown Icon Why are some ABC type parts no longer being included in the Cycle Count?
DrillDown Icon Physical Inventory
DrillDown Icon Standard Cost Adjustment
DrillDown Icon Part Manufacturer Setup
DrillDown Icon Material Planning
DrillDown Icon Production
DrillDown Icon Quality/Engineering
DrillDown Icon Administration
DrillDown Icon eManEx
DrillDown Icon ManEx Minutes for All Modules
  Email This ArticlePrint PreviewPrint Current Article and All Sub-Articles
 
How can I clear out a Cycle Count that was started in error?

For Example, a user has begun the Cycle Count process by pulling items fwd into the module for counting by accident, but for what ever reason, you do not wish to continue on with the reconciliation process of the count.  But now those parts are locked in a count and will not be editable throughout the system (Kitting, PO Receiving, Inventory Handling, etc. . . )  If the part is locked in a count you will see messages similar to the below throughout the system.

If you wish to Purge the Cycle Count out of the system you can run the below procedure and any record that has not had a count entered into the Cycle Count module will be cleared.


SQL Manex Only

Within SQL Manager run the following:

exec sp_ClearAllCC



VFP Instructions Only

Please be sure to follow the procedure below to install this program.  It is highly recommended that you follow this procedure on your TEST system first before applying it against your Live ManEx System.

1.)                 Create a Backup of your Live ManEx System

2.)                 Extract << purgecc9.exe>> into the ManEx Root Directory

3.)                 Run the Executable

4.)                 Verify the Results

5.)                 Remove << purgecc9.exe>> from the ManEx Root Directory

Once satisfied with the results in your test system, you may proceed with your Live ManEx System.  Please let me know if you have any questions.

 